Garage Door Opener RFI Kit

Solar Micro-inverter/PV Module Noise Filters (2)-ID=1.4" Ring, 1/2" Snap On

SKU RFI-PV-MI
$24.95
Bulk pricing available for quantities of 10 units or more
1
Buy more, save more
QuantityPrice per itemDiscount
10 items$21.9912% off
50 items$19.9520% off
100 items$18.9524% off
Save this product for later
Share this product with your friends
Solar Micro-inverter/PV Module Noise Filters (2)-ID=1.4" Ring, 1/2" Snap On
Product Details
MPN: RFI-PV-MI
Type: New
Country/Region of Manufacture: United Stats
Filter Power Rating (PEP watts): not applicable
RFI Suppression Range (MHz): .1-10
Enclosure Size (inches): none

The RFI kit is designed to suppress RFI caused by Solar micro-inverters, power optimizer, and solar arrays by electrically isolating the “antenna” wires used to connect the various devices.The cabling between the PV array, the micro-inverters or power optimizers and their connection to the electrical bus combining their individual outputs can be considered “antennas” for the pulse switching circuits of the individual devices thereby causing radiation at very low fundamental frequencies with harmonics that can cause undesirable radio interference in the 1-30 MHz (and sometimes higher) frequency range.This interference may be objectionable to the owner of the solar installation as well as neighbors who may also experience the interference to their electronic devices.

THE RFI KIT FILTERS ONLY SUPPRESS COMMON MODE CURRENT (SIGNALS) THAT ARE COMMON TO ALL WIRES IN THE CABLE, AND DOES NOT EFFECT INDIVIDUAL DIFFERENTIAL SIGNALS ON EACH WIRE. THE FILTERS HAVE NO EFFECT ON THE NORMAL SIGNALS CARRIED WITHIN THE CABLE.

Micro-inverter RFI

Ferrite cores (snap on) are snapped over the two (+/-) cables from the solar array module and the two wires hooked to the “string” connecting the micro-inverters together. Suppressing RFI on all wires in and out of the micro-inverters helps to reduce any broadband RFI “noise” generated in the SOURCE switching circuits (typically at 50-200KHz and harmonics thereof). Two ferrite cores are required for each micro-inverter/PV array – one ring for the PV DC cables and a snap on for the micro-inverter cable to the string bus – size to fit the trunk cable with 1 or 2 turns.

Application Note for Enphase M190/M215/M240/M250 series Micro-inverters (and similar other brands). For each PV array/micro-inverter use a RFI-PV-MI filter kit with a ring (ID=1.4″/36MM) ferrite for installation on PV module DC cables to micro-inverter and a snap on (ID=.4″/10mm) filter for the data/trunk cable output of the micro-inverter. At the connection of each junction box and the Engage cable install a RFI-PV-JB filter (ID=1″/26MM) with multiple turns through the center.

Christmas lights or yard lights with switching DC power supplies are often the RFI source and a clamp on ferrite bead on the AC AND the DC side feeding the lights is needed to help suppress the switching power supply RFI noise.  Suitable snap on beads are FSB31-1/2 for the 1-250 MHz range.

We have also had reported wireless HDTV boxes, and FOSCAM and AMCREST security camera systems causing RFI to garage door remote openers. Use our Garage Door Opener RFI kit to suppress the interference to the opener (VICTIM) – you need one kit for each opener.  Maximize the distance from the camera to the openers may also help.  Additionally shield cable to the garage door sensors may be needed depending on severity of the camera RFI.

Obvious Tech Note: make sure your remote batteries have enough energy to activate the GDO or the signal they transmit may not be large enough to over ride the RFI signal, but a fresh battery may be able to overcome the weak RFI source and allow the GDO to operate correctly.