Iron Powder Cores

16:1 Baluns are useful between 750-850 ohm balanced loads where the impedance at the end of the feed line is 800 ohms (1/2 wavelength feed line), or high impedance feeds for rhombic, T2FD and traveling wave antennas.

16:1 Ununs are useful between coax and long wires with a load impedance near 800 ohms like a beverage antenna. Shortwave listener antennas also can benefit with the 16:1 unun and it may provide a better match than 9:1 ununs – this means quieter noise levels and stronger signals so you can hear distance stations easier.

16:1 transformers are made to order with manufacturing time of 5 or more days before shipment depending upon quantity.

Refine by
 

Filters

Filters
IRON POWDER TOROID CORES-xx

Iron Cores 150x150 - Iron Powder CoresIron powder cores are more stable than ferrites and do not saturate as easily so they are best for tuned circuits, filters, and high power inductors. They come in different “Mixes” for use at different frequencies. For best “Q” use the Mix specified for your frequency.To find the number of turns to give the desired inductance for your coil use the formula below:

 

Turns = 100 x iron core formula 300x14 - Iron Powder Cores

Toroid Dimensions

tcolorcode - Iron Powder Corestcore - Iron Powder Cores

 

To order specify core size and mix (e.g. T200A-2). Available in sizes that have µH per 100 turns shown in table.

All iron powder cores are special orders.  Please allow one week for shipment after order received.

The iron powder cores shown in the above tables are primarily used for either high power feed line chokes for common mode current reduction or for 4:1  and 9;1 very high power transmission line transformers.

For high power feed line chokes, choose the inside diameter of the iron powder core closest to the transmission line outside diameter and use 6-20 cores at the junction with the antenna feed.

For 4:1 (50/200 or 75/300 ohm) transmission line transformers in the range of 1.8-30 Mhz, select the size appropriate for the power level as follows:

T200A x 2 = 1.5KW

T300A x 2 = 2.5KW

T400A x 2 = 5KW

Use Mix 2 for all the above transmission line transformers.  Fully assembled and enclosed units are available for each of the power levels.  Click HERE for information.

4:1 transmission line transformers using iron powder cores are typically used for ladder line to 50 ohm coax connections

For .1 – 2 Mhz wide band transformers use Mix 26 which has a higher permeability and requires less turns to achieve a given inductance. Mix 2 has almost constant permeability from 1-30 Mhz.  Mix 26 has an initial permeability of 75 at .1 Mhz and gradually decreases to about 10 at 30 Mhz.  For high power AM broadcast range (.5-1.7 Mhz) transformer, use Mix 26 to reduce the turn count.

Minimum order for iron powder cores is $50  

Shipping on larger cores in quantity may be more than $10 – email/call for quote.