Impedance Transformers (<1:1, >1:1)

Slip On Coax Feed Line Choke - 1"/25.4mm cable, 1.8-300 MHz

SKU BA-200-5
$109.95
On Sale
List price $149.95 Save 27%
Bulk pricing available for quantities of 3 units or more
Select # of beads
1
Buy more, save more
QuantityPrice per itemDiscount
3 items$99.959% off
10 items$89.9518% off
Save this product for later
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
Share this product with your friends
Slip On Coax Feed Line Choke - 1"/25.4mm cable, 1.8-300 MHz
Product Details
Brand: Palomar Engineers
MPN: BA-200
Country/Region of Manufacture: USA
Effective Frequency Range (MHz): 3-61 (5 bead), 1.8-61 (10, 15 bead)
PEP Power Rating (watts): same as coax cable rating
Choking Impedance Range (ohms): 5 bead: 200-900, 10 bead: 400-1400, 15 bead: 600-1700
Common Mode Attenuation (db): 5 bead: 9-20 db, 10 bead: 16-24 db, 15 bead: 17-25 db
Estimated Insertion Loss (db): .025
Input Connector Type: none
Output Connector Connector Type: none
Ground Connector (Y/N): none
Enclosure Size (LxWxH inches): none

1″/25.4mm max Cable Size Chokes

Model BA-200. For use with RG-218 and similar size cables up to 1" OD without connectors installed. Works on all impedance cables, 1.8-300 MHz. Choke outside diameter is 2 inches Requires 9-1/2 inches of cable for 5 bead version, 17" of cable for 10 bead version, and 25" of cable for 15 bead version. Use BA-200-10 or BA-200S-15 for higher choking below 21 MHz. For 10-12 meter frequency use 5 beads up to 15 KW PEP, 10 beads for up to 30 KW PEP and 15 beads for up to 45 KW PEP. We use mix 31 for all chokes. Heat shrink weather proofing kit included. Picture shows 10 bead version.

Rule of thumb suggests you need minimum 5x-10x the coax line impedance for effective choking and the more the better as it will reduce common mode current with higher choking impedance. Select chokes with minimum of 500 ohms at your frequency of interest for best results or upgrade to our CUBE(TM), TUBE(TM), Super Choker(TM) chokes up to 15,000 ohms choking.

Select 10 bead version for 160 meter use, 15 bead version for even higher choking power on lower frequencies. Power rating is same as coax cable used power rating.

Typical choking impedances (BA-58, BA-8, BA-200):

Ba 8 Comparison png - Impedance Transformers (<1:1, >1:1)



Palomar Engineers offers a variety of impedance transformers configured as Baluns (balanced coax to unbalanced load) or Ununs (unbalanced coax to unbalanced load) for  matching typical 50 ohm feed line impedances to antenna or other load impedances.

We specify impedance ratios as an output to input ratio where the output (or load) is given first and the input is given second (e.g. 100:50 (2:1) would mean a 100 ohm output and a 50 ohm input; a 25:50 (1:2) would mean a 25 ohm load and a 50 ohm input).  Most all products use a 50 ohm input unless otherwise specified.

We have products that are available as kits for the do-it-yourself (DIY) person or fully assembled and tested units for the “Plug & Play” crowd.

Our impedance transformers are available using two different topologies: Binocular cores or  toroid cores with multiple turns for increased effectiveness and wide band frequency transformations.  We utilize single and multiple core transformers using high order windings when needed to extend product performance.

We rate the power ratings as watts PEP (Peak Envelop Power) with standard duty cycles for various modes. To determine the PEP rating required for your needs, see: Choke & Transformer Power Ratings

This website page serves as a link page to the frequency ranges of our impedance transformers configured as either baluns or ununs.  You can click on a picture to go to the specific page about the products described in the picture.