Wall Wart RFI Noise Filter

CUBE 1:1 Feed Line Choke Balun, 5KW, 1.8-61 MHz, -38dB Common Mode Rejection, Eyebolts/Top Studs Options

CB-1-5000EB
$139.95
In stock
1
Product Details
Brand: Palomar Engineers
Effective Frequency Range (MHz): 1-61 MHz
PEP Power Rating (watts): 5000
Estimated Insertion Loss (db): .10
Input Connector Type: SO-239 female
Output Connector Connector Type: top studs or side eyebolts
Ground Connector (Y/N): none
Enclosure Size (LxWxH inches): 4 x 4 x 4

5000 Watt rated 1:1 CUBE™ BALUN

* Help keep RF out of the shack.

* Provides maximum transfer of RF to the antenna.

* Suppress radiation from the feeder cable

* Makes the antenna radiation pattern predictable.

* Reduces QRN and TVI to the neighbors.

This higher power BALUN or UNUN utilizes mil-spec coax cable for the windings on a triple core toroid with coax silver shield and silver braid for low loss. The dielectric is Teflon® insulation for high voltage ratings of 1,900 volts. (A typical 5KW signal at 50 ohms impedance will have a voltage of 500 volts at 1:1 SWR). Available wired as a BALUN (CB-1-5000) with wire studs output or as a UNUN (CU-1-5000) with SO-239 input and output connectors. Rated 5KW PEP/1500 Watts AM/RTTY/CW/FT-8 from 1.8-30 Mhz, less at 50 Mhz. Enclosure is 4" x 4" x 2"

If you run RTTY contests at 1500 watts output, this is the balun/unun you need – it won’t burn out at heavy 1500 watt duty cycles like other brands rated at 1500 watts (or more). We use these same chokes in our own RTTY station at full 1500 watts output and they have never failed. We use one at the amplifier output and another at each antenna feed point. Works very well on OCF antennas below the 4:1 balun to keep RF current on the antenna and off the feed line. Built like a tank, works like a charm, and priced under the competition – what more can you ask for? THIS IS OUR MOST POPULAR 1:1 BALUN!

Save this product for later
Wall Wart switching DC power supplies that plug into the AC power line plug and provide DC power to laptops, routers, battery chargers, cell phone chargers, etc are a known source of broadband RFI (a.k.a dirty electricity) that effects many electrical devices including computers, radio receivers, HDTV systems, etc.  In many cases this extra RFI noise effects computer I/O speeds since they have to error correct the information packets many more times due to the noise interference causing packet errors.  A ferrite ring can often increase data throughput by reducing the error correction to normal rates.

A simple ferrite ring filter on the DC power line can help suppress the RFI noise affecting the victim device or keep the DC power cord from acting as an antenna and radiating RFI into other victim devices. This kit is also useful on laptop computer supplies, routers, cable modems, wireless phone charges, etc.

RFI WW Installation 300x288 - Wall Wart RFI Noise Filter

Installation is quick and easy: Just wrap the DC power cord through the center of the ring filter as many times as you can and reinstall.  For best results with long DC power lines, use one at the ring filter at the wall wart end (to prevent the wall wart power supply from using the DC line as an antenna) and another at the DC plug end (to prevent the electronics in the powered device from using the DC power cord as an antenna).  Typical installation is shown below:

The filter suppresses RFI in from .1-100 MHz.   Inside diameter is 3/4 inch/19 mm.

Since most households and office environments have multiple wall warts we offer the Wall Wart RFI Filter kit in bulk quantity packages.

Known RFI Generators include Roku/Sling-TV power adapter - Interference heard in the AM broadcast band
 and harmonics.
Also many ethernet Cable/DSL modems, cell phone chargers, computer power adapters have the same issue:
using the AC or DC side of the power supply as a radiating antenna.

RFI solution is to use a linear power supply, change adapters or wall wart ferrite filters