Wall Wart RFI Noise Filter

20-6 Meter Loop Antenna System with 4:1 Balun and Choke Combo, (20, 17, 15, 12, 11, 10, 6 meters) 500/1.5KW/5KW PEP Options

PAL-LOOP2006-500
$149.95
In stock
1
Product Details
MPN: PAL2010LOOP-500, -1500, -5000
Country/Region of Manufacture: USA
Input ohms/Output ohms: 50 in/200 out
Frequency Range < 2:1 SWR (MHz): 1.8-61MHz
PEP Power Rating (watts): 500/1.5KW/5KW
Input Connector: SO-239
Output Connector(s): Eyebolts/Wing Nut
Hardware Type: Stainless Steel
Enclosure Size: 4"x4"x 2"(1.5KW), 4"x 4" x 4"(5KW)
Weight (pounds): 3#(500)/4#(1.5KW)/5#(5KW)

20-6 Meter Loop antenna (72' wire) + 500/1500/5000 Watt PEP rated 4:1 Current Balun + internal 1:1 Current Balun in one enclosure + 4 insulators for support

* Complete package - just add coax

* works multiple bands with ease

* can be configured as delta, square, rectangle or multi-sided horizontal loop (4 insulators included)

* Choice of 500, 1.5KW or 5KW PEP rated HYBRID baluns to suit power needs

* No need for extra feed line choke as it is built into the 4:1 balun enclosure

After many requests we have created a compact, special balun for OCF and loop (Skyloop or Delta loop) antennas. The CB-4-1-1500/5000 is a CUBE enclosure containing a multi-core, broadband 4:1 impedance transformer in series with a 1:1 current balun for extra common mode current choking to keep RF current off the outside of the coax braid and on the antenna where it belongs. The extra choking action also means that the coax feed line will not act as a radiator causing unnecessary RF interference (RFI).

1.5KW Rated for full 1500 watts PEP and 1000 watts CW/FT8 (ICAS). 1.8Mhz – 61 MHz.

5KW Rated for full 5000 watts PEP and 1500 watts CW/FT8 (ICAS). 1.8Mhz – 61 MHz.

500 watt version is in "BULLET" format, 1.5KW is a 4 x 4 x 2 cube and 5KW is in 4" x 4" x 4" enclosure.

Save this product for later
Wall Wart switching DC power supplies that plug into the AC power line plug and provide DC power to laptops, routers, battery chargers, cell phone chargers, etc are a known source of broadband RFI (a.k.a dirty electricity) that effects many electrical devices including computers, radio receivers, HDTV systems, etc.  In many cases this extra RFI noise effects computer I/O speeds since they have to error correct the information packets many more times due to the noise interference causing packet errors.  A ferrite ring can often increase data throughput by reducing the error correction to normal rates.

A simple ferrite ring filter on the DC power line can help suppress the RFI noise affecting the victim device or keep the DC power cord from acting as an antenna and radiating RFI into other victim devices. This kit is also useful on laptop computer supplies, routers, cable modems, wireless phone charges, etc.

RFI WW Installation 300x288 - Wall Wart RFI Noise Filter

Installation is quick and easy: Just wrap the DC power cord through the center of the ring filter as many times as you can and reinstall.  For best results with long DC power lines, use one at the ring filter at the wall wart end (to prevent the wall wart power supply from using the DC line as an antenna) and another at the DC plug end (to prevent the electronics in the powered device from using the DC power cord as an antenna).  Typical installation is shown below:

The filter suppresses RFI in from .1-100 MHz.   Inside diameter is 3/4 inch/19 mm.

Since most households and office environments have multiple wall warts we offer the Wall Wart RFI Filter kit in bulk quantity packages.

Known RFI Generators include Roku/Sling-TV power adapter - Interference heard in the AM broadcast band
 and harmonics.
Also many ethernet Cable/DSL modems, cell phone chargers, computer power adapters have the same issue:
using the AC or DC side of the power supply as a radiating antenna.

RFI solution is to use a linear power supply, change adapters or wall wart ferrite filters