Antenna Static Bleeders

Ladder Line baluns are used to match the impedance seen at the end of the ladder line to a coaxial cable, usually 50 ohms, but a ladder line balun can also be used to match to 75 ohm coax like RG-6/U used for cable and satellite installations. While RG-6 doesn’t have the same power rating as larger cable, it is very useful for beverage antennas or receiving antennas which don’t carry a lot of power.

The impedance seen at the end of the ladder line will not be the same as the characteristic impedance of the ladder line (typically 300 or 450 ohms). Good ladder line antenna designs try to have the impedance at the end of the ladder line attachment to the balun close to 200 ohms so that a 4:1 balun can be used to match to 50 ohm coax.

A typical ladder line antenna is shown in the picture below:

Ladder Line antenna Diagram - Antenna Static Bleeders

Palomar Engineers has ladder line to coax 4:1 baluns in both kit form and also assembled in a variety of 1 watt to 10KW power levels to suit the needs of many customers. The ladder line baluns are designed for balanced output and are generally used at the end of a run of ladder line from the antenna. The baluns connect to the ladder line and then transition to coax cable to you antenna tuner or radio station.

Refine by
 

Filters

Filters

Due to many requests for antenna static bleeders, we have developed a product line of static bleeders for coax and for ladder line applications.  Static electricity is caused by many situations including high desert wind, atmospheric conditions, etc.  You may hear static crashes or have a buildup of static electricity that my be annoying during a radio conversation and it may be harmful to solid state electronics if high voltages are present on the RF input to your equipment.

A static “Bleeder” which shorts the direct static voltage to ground while leaving the RF frequency voltage unaffected if very beneficial particularly to those operations in desert conditions where low humidity, high static buildup are quite common.  The SB-1 and SB-2 coax static bleeders work on coax line and the SB-3 static bleeder is meant for ladder line.

THESE DEVICES ARE NOT FOR LIGHTNING PROTECTION AND PROVIDES NO PROTECTION FOR LIGHTNING STRIKES!!!!!

Ladder Line baluns are used to match the impedance seen at the end of the ladder line to a coaxial cable, usually 50 ohms, but a ladder line balun can also be used to match to 75 ohm coax like RG-6/U used for cable and satellite installations. While RG-6 doesn’t have the same power rating as larger cable, it is very useful for beverage antennas or receiving antennas which don’t carry a lot of power.

The impedance seen at the end of the ladder line will not be the same as the characteristic impedance of the ladder line (typically 300 or 450 ohms). Good ladder line antenna designs try to have the impedance at the end of the ladder line attachment to the balun close to 200 ohms so that a 4:1 balun can be used to match to 50 ohm coax.

A typical ladder line antenna is shown in the picture below:

Ladder Line antenna Diagram - Antenna Static Bleeders

Palomar Engineers has ladder line to coax 4:1 baluns in both kit form and also assembled in a variety of 1 watt to 10KW power levels to suit the needs of many customers. The ladder line baluns are designed for balanced output and are generally used at the end of a run of ladder line from the antenna. The baluns connect to the ladder line and then transition to coax cable to you antenna tuner or radio station.

Refine by
 

Filters

Filters