Hybrid 4:1 Balun + 1:1 Current Balun in one enclosure, 1.8-61 MHz, 1.5/5KW PEP - Loop, OCF Antennas
After many requests we have created a compact, special balun for Off Center Fed (OCF) , loop (Skyloop or Delta loop) , BBTD, T2FD, folded dipoles antennas. The CB-4-1-1500 is a CUBE(TM) enclosure containing a multi-core, broadband 4:1 impedance transformer in series with a 1:1 current balun for extra common mode current choking to keep RF current off the outside of the coax braid and on the antenna where it belongs. The extra choking action also means that the coax feed line will not act as a radiator causing unnecessary RF interference (RFI). Rated for full 1500 watts PEP and 1000 watts CW (ICAS). 1.8Mhz – 61 MHz.
CB-4-1-1500 is housed in a 4” x 4” x 2” waterproof housing with SO-239 input and stainless steel eye bolts on the side for ease of connection to your wire antenna. Top eye bolt acts as an antenna hoist.
5KW are in 4" x 4" x 4" enclosure. 1.5KW is 2 pounds, 5KW is 4 pounds.
For an 80 meter OCF antennas we recommend a (95 feet/79.5% and 40 feet/29.5% offset for best all band results. If you use 66%/34% offset, do not use on 15 meters as the impedance mismatch may damage the balun at high power levels. Loop antennas should be cut for 1005/F(MHz) in total length, where F (MHz) is the lowest frequency to be used. For 3.5MHz this equates to 288 feet.
We highly recommend a feed line choke (MC-1-3000) or coax noise filter (CMNF-1500) at the radio end of the coax feed line to reduce common mode noise picked up by the coax braid.
CB-4-1-5000EB/TS are custom made to order - please allow 7-10 days ARO before ship.
Customer testimonial:
Callsign: NE5U Your CB-4-1500 +1:1 Choke made my homebrew, hail mary, 3 times folded 75m resonant attic dipole into a functional antenna from 6m to 160m. Most bands I can operate with no RFI. I've installed ferrites at all of the usual locations but still have some problem bands. Considering that the antenna is, at best, an NVIS antenna, I have made a lot of DX contacts (SSB, FT8 and other digital modes, and CW). Happy customer here. 73
50 ohm coax to 75 ohm balanced output baluns are useful for low (< 1 wavelength) dipoles exhibiting 75 ohm characteristic impedance or for matching to balanced ladder line whose endpoint impedance is near 75 ohms.
50 ohm coax to 75 ohm CATV coax connections are easily done with a 1.5:1 unun with SO-239 connectors on input and output. Likewise 50 ohm coax to unbalanced verticals or loads near 75 ohms can be matched with a 1.5:1 unun.