RF Toroid Calculator by VK3CPU
Snap On RF Choke/Isolator - 3/8"/9mm cable, 5/10/15 Bead Option, 1-300 MHz
SNO-3/8-5
$17.95
In stock
1
Product Details
Brand:
Palomar Engineers
MPN:
SNO-3/8-5
Effective Frequency Range (MHz):
3-300
PEP Power Rating (watts):
same as coax cable rating
Choking Impedance Range (ohms):
5 bead: 500-100, 10 bead: 600-1800, 15 bead: 1000-2100
Common Mode Attenuation (db):
5 bead: 16-22db, 10 bead: 17-25db, 15 bead: 21-27 db
Estimated Insertion Loss (db):
.025
Input Connector Type:
none
Output Connector Connector Type:
none
Ground Connector (Y/N):
none
Enclosure Size (LxWxH inches):
none
Use for 3/8″ Cable – RG-8X, LMR-240, etc
For 3/8” cables use five FSB31-3/8 split beads for 80-10 meters (3-30 mHz) or ten FSB-3/8 split beads for 160-10 (1.8-30 MHz) meters or use 15 FSB31-3/8 for even higher choking for 1-10 MHz.
Typical Impedance per split bead: 10 MHz: 100 ohms, 25 MHz: 163 ohms, 100 MHz: 275 ohms, 250 MHz: 275 ohm
Minimum recommended total impedance is 500 ohms at frequency of interest.
The beads clamp to the cable and may be operated as is for indoor use. However, it is strongly suggested that they be covered to protect the plastic covers from weathering – use electrical tape for best results or heat shrink to ensure longer life. All kits come with instruction manual which covers assembly and application tips.
As you can see from the impedance vs frequency graph, you can very effectively increase the choking impedance by increasing the number of beads on the cable.
Save this product for later
Display prices in:
USD
Tutorials
Snap On RF Choke/Isolator - 3/8"/9mm cable, 5/10/15 Bead Option, 1-300 MHz
Use for 3/8″ Cable – RG-8X, LMR-240, etc
For 3/8” cables use five FSB31-3/8 split beads for 80-10 meters (3-30 mHz) or ten FSB-3/8 split beads for 160-10 (1.8-30 MHz) meters or use 15 FSB31-3/8 for even higher choking for 1-10 MHz.
Typical Impedance per split bead: 10 MHz: 100 ohms, 25 MHz: 163 ohms, 100 MHz: 275 ohms, 250 MHz: 275 ohm
Minimum recommended total impedance is 500 ohms at frequency of interest.
The beads clamp to the cable and may be operated as is for indoor use. However, it is strongly suggested that they be covered to protect the plastic covers from weathering – use electrical tape for best results or heat shrink to ensure longer life. All kits come with instruction manual which covers assembly and application tips.
As you can see from the impedance vs frequency graph, you can very effectively increase the choking impedance by increasing the number of beads on the cable.