Iron Powder Cores

Termination Resistor, 500 Ohm Non-Inductive for T2FD, BBTD, Rhombic, 1-61 MHz, 600 Watts

TR-500-600
$99.95
In stock
1
Product Details

Broadband, Non-Inductive Termination Resistor load used on many terminated antenna types such as T2FD, Broadband Terminated Dipole (BBTD), Rhombics and others

Resistive Value: 500 ohms (+/- 10%)

SSB (25% duty cycle) rating in Watts: 600

CW/FT8 (50% duty cycle) in watts: 400

Length (tip to tip) Inches: 14"

Width inches: 3"

Inductance < 20 nH (1-61 MHz)


Internal Resistance Wattage: 200 watts

If you need more power rating, consider putting two TR-1000-600 resistors in parallel for a total of 1200 watts at 500 ohms.

Many designs for BBTD antennas using termination resistors at HFLINK.COM

Excellent BBTD Install info by K1FU

Save this product for later
IRON POWDER TOROID CORES-xx

Iron Cores 150x150 - Iron Powder CoresIron powder cores are more stable than ferrites and do not saturate as easily so they are best for tuned circuits, filters, and high power inductors. They come in different “Mixes” for use at different frequencies. For best “Q” use the Mix specified for your frequency.To find the number of turns to give the desired inductance for your coil use the formula below:

 

Turns = 100 x iron core formula 300x14 - Iron Powder Cores

Toroid Dimensions

tcolorcode - Iron Powder Corestcore - Iron Powder Cores

 

To order specify core size and mix (e.g. T200A-2). Available in sizes that have µH per 100 turns shown in table.

All iron powder cores are special orders.  Please allow one week for shipment after order received.

The iron powder cores shown in the above tables are primarily used for either high power feed line chokes for common mode current reduction or for 4:1  and 9;1 very high power transmission line transformers.

For high power feed line chokes, choose the inside diameter of the iron powder core closest to the transmission line outside diameter and use 6-20 cores at the junction with the antenna feed.

For 4:1 (50/200 or 75/300 ohm) transmission line transformers in the range of 1.8-30 Mhz, select the size appropriate for the power level as follows:

T200A x 2 = 1.5KW

T300A x 2 = 2.5KW

T400A x 2 = 5KW

Use Mix 2 for all the above transmission line transformers.  Fully assembled and enclosed units are available for each of the power levels.  Click HERE for information.

4:1 transmission line transformers using iron powder cores are typically used for ladder line to 50 ohm coax connections

For .1 – 2 Mhz wide band transformers use Mix 26 which has a higher permeability and requires less turns to achieve a given inductance. Mix 2 has almost constant permeability from 1-30 Mhz.  Mix 26 has an initial permeability of 75 at .1 Mhz and gradually decreases to about 10 at 30 Mhz.  For high power AM broadcast range (.5-1.7 Mhz) transformer, use Mix 26 to reduce the turn count.

Minimum order for iron powder cores is $50  

Shipping on larger cores in quantity may be more than $10 – email/call for quote.