1:1 Baluns/Ununs/Chokes

Snap On End Fed Feed Line Choke for Non-Resonant and End Fed Half Wave Antennas, RG8X, RG8, up to 38 dB common mode suppression

SKU SOFLC
$19.50
Bulk pricing available for quantities of 3 units or more
1
Buy more, save more
QuantityPrice per itemDiscount
3 items$16.9513% off
Save this product for later
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
Share this product with your friends
Snap On End Fed Feed Line Choke for Non-Resonant and End Fed Half Wave Antennas, RG8X, RG8, up to 38 dB common mode suppression
Product Details
MPN: SOFLC

SNAP On Feed Line Choke

Each end fed antenna needs a feed line choke at the radio end of the coax to stop the antenna common mode current (on the coax braid) from getting into the radio when transmitting and also to stop RFI common mode noise when receiving. A
simple easy to adjust in different places along the coax used as a counterpoise is the snap on ferrite core with a 1" ID (hole) installed as shown in the picture. (coax not included, but you can use RG-8X size for 5 turns and RG-8X size for 3 turns).

Add the Feed line choke (part # SOFLC) to your end fed antenna today today and stop the pesky RFI from getting into your radio and causing RFI, audio distortion or unexpected operation!


NOTE: Coax shown in picture is NOT INCLUDED and is shown as an installation example only. If you want a pre-wound choke check part# JC-1-1500-3 or JC-1-1500-6.


For non-resonant end fed antennas placement of the choke from 10-50 feet away from the antenna feed point to use the coax braid as the counterpoise (since these antennas are really off center fed dipoles with the short side using the coax braid as the count5erpoise. Wind 8-10 turns thru center for an effective 3-30 Mhz choke.


For End fed Half Wave antennas place 3-10 feet from antenna feed point to act as short counterpoise for these voltage fed antennas. Use 8-10 turns.


TECH NOTE: SNAP On Chokes for 80 and 160 meter end fed antennas

If you use RG-8X size cable, use 2 SOFLC if you have 5-6 turns thru the center of each.See picture on left as an example of how to wind the cable.

Double SOFLC for 80OCF jpg - 1:1 Baluns/Ununs/Chokes

Measure 40 feet from the matching unun and then wind 6 turns thru the center of the SOFLC.Close it up and then wind an additional 6 turns thru another SOFLC placed adjacent to the first one and on the radio station side of the coax.See picture to left.

If you use LMR-400 or 1/2" coax cable you will only get 3 turns thru the snap on choke and you will need an additional choke (with an additional 3 turns) in series to provide enough choking on 40 and 80 meters. Part# SOFLC.

SOFLC x 2 for LMR400 jpg - 1:1 Baluns/Ununs/Chokes

In lieu of the 2 chokes shown above, you may also use a F400-31 ring (3” ID) with 6 or more turns which provides a much higher common mode suppression and better antenna tuning on 80 meters. See picture for winding example.

SC 1 5000 Product png - 1:1 Baluns/Ununs/Chokes

HF 1-61 MHz coax feed line common mode chokes

1:1 feed line Chokes (also known as feed line current chokes, common mode chokes, line isolators, current mode chokes, and 1:1 baluns/ununs) are available in kit form or assembled form in a weatherproof Current Unun and Balun Enclosure which we call a CUBE™. All 1:1 chokes are ferrite based and are designed for 50 ohm coaxial cable input and 50 ohm output. 1:1 Ferrite toroidal or bead chokes have a higher choking impedance than our popular Sleeve Chokes and various models are available for specific frequency ranges and power levels.

1:1 Chokes are useful for choking common mode currents that may flow on the exterior of the coax cable shield while allowing the signals on the interior of the shield and the center conductor to flow unaffected and keeping the common mode current on the antenna. They isolate the coax shield and prevent it from becoming part of the antenna system.  

1:1 Chokes are useful between balanced lines for center fed dipoles at their fundamental frequency (468/f (MHz), beam antennas with a 50 ohm balanced driven element, G5RV, loops, yagis, NVIS antennas, mobile installations, portable antennas and anywhere common mode current (or RFI) is a problem.  They are also helpful between transmitter and linear amplifier or between linear amp and antenna tuner or as isolation chokes where higher choking impedance is needed (in the range of 2K-7K ohms). 

1:1 Chokes are also very useful as feed line current chokes at the “radio end” of the antenna (we call them coax noise filters) where they choke/filter common mode current induced onto the coax shield from radiated waves (from your antenna, and other sources such as DSL routers, computer devices, plasma TVs, etc. originating in your house or your neighbor’s house).  For RFI issues see RFI/EMI Solutions for general use or for specific radios and devices.  

For best results we recommend a 1:1 choke at the “antenna end” of the coax and a coax noise filter at the “radio end” of the coax. (A side benefit is a reduction in noise level caused by common mode currents). 1:1 chokes are also available as Sleeve Chokes (Slip on or Snap on) for ease of installation and light weight on the antenna.